24V 4200W 48V 6200W Main Control PCBA Mainboard
Hybrid Solar Inverter PCBA Specifications


- This device is a hybrid inverter/charger that combines <Functions of Inverter/Solar Charger/AC Charger/UPS uninterruptible power supply>.
- Featuring a comprehensive LCD display, it provides user-configurable and easily accessible operation buttons for functions such as battery charging current, AC/solar charger priority, and acceptable input voltage and parameter settings based on different applications.
Applications:Rooftop photovoltaics, RVs, camper vans, yachts, household appliances, power tools, office and portable devices, and other fields!
Features
- Pure sine wave output
- Configurable DC input voltage range
- Configurable battery charging voltage
- Configurable battery floating charge voltage
- Configurable battery charging current
- Configurable battery hybrid charging
- Configurable AC/solar charger priority
- Configurable AC output voltage
- Configurable AC output frequency
- Configurable UPS mode switching priority
- Configurable LCD display mode
- Configurable energy-saving mode,supporting operation with PV but without a battery,featuring complete protection circuits and monitoring systems
- Smart battery charger design (optimizes battery performance,battery balancing mode,lithium battery discharge reactivation)
Electrical Specifications
| Table 1: AC Line Mode Specification Table(UPS Bypass or Charge) | ||
|---|---|---|
| Specifications and models | 0918PCBA-4.2KW | 0918PCBA-6.2KW |
| Rated output power | 4.2KW | 6.2KW |
| Input voltage waveform | Pure sine wave | |
| Nominal input voltage | 24Vac | 48Vac |
| Low loss voltage | 170Vac±7V (UPS bypass); 90Vac ±7V (Appliances) | |
| Low loss return voltage | 180Vac±7V (UPS bypass); 100Vac±7V (Appliances) | |
| High loss voltage | 280Vac±7V | |
| High dissipating loop voltage | 270Vac±7V | |
| Maximum AC input voltage | 300Vac | |
| Nominal input frequency | 50Hz/60Hz (Automatically detect) | |
| Low loss frequency | 40±1Hz | |
| Low loss return frequency | 42±1Hz | |
| High loss frequency | 65±1Hz | |
| High loss return frequency | 63±1Hz | |
| Output short-circuit protection | breakers | |
| Efficiency (Line Mode) | 90% (Rated R-load, battery fully charged ) | |
| UPS switchover time | 10ms (UPSbypass); 20ms (Appliances) | |
| Output power reduction: When the AC input voltage drops to 170V, the output power will decrease. Derating curve diagram→ | ![]() |
|
| Table 2: Inverter mode form | ||
|---|---|---|
| Specifications and models | 0918PCBA-4.2KW | 0918PCBA-6.2KW |
| Rated output power | 4.2KW | 6.2KW |
| Output voltage waveform | Pure sine wave | |
| Output voltage | 220V/230V/240V (default 230Vac, configurable) | |
| Output frequency | 50Hz/60HZ | |
| Highest efficiency | 90% | 93% |
| Overload protection | 5.5s@≥150%~200%Load; 10.5s@110%~150%Load; | |
| Surge capacity/peak power | 1 times/(2 x Rated power for 5 s) | |
| DC input voltage range | 20Vdc-33Vdc | 40Vdc-63Vdc |
| DC cold start POWER boot voltage | 22.0Vdc | 44.0Vdc |
| Low pressure tips | Load≥ 50% 21.0Vdc || Load <50% 22.0Vdc | Load≥ 50% 42.0Vdc || Load <50% 44.0Vdc |
| Low pressure indicates recovery | 22.0Vdc | 44.0Vdc |
| Undervoltage protection/shutdown | Load≥ 50% 20.0Vdc || Load <50% 21.0Vdc | Load≥ 50% 40.0Vdc || Load <50% 42.0Vdc |
| Undervoltage recovery/power-on | Reset Power | |
| Battery overvoltage recovery | 32.0Vdc | 62.0Vdc |
| Battery overvoltage protection | 33.0Vdc | 63.0Vdc |
| No-load power consumption | ≈0.7A | ≈0.5A |
| Table 3: Charging Modes form | ||
|---|---|---|
| 1)Public grid charging mode | ||
| Specifications and models | 0918PCBA-4.2KW | 0918PCBA-6.2KW |
| Grid charging mode | 3-stage | |
| Maximum Charging Current (AC) | 80A (60A can be set by default) | |
| Maximum Charging Voltage (C.V) | 28.2Vdc(Default/Configurable) | 56.4Vdc(Default/Configurable) |
| Floating charge voltage | 27.0Vdc(Default/Configurable) | 54.0Vdc(Default/Configurable) |
| 2)MPPT solar charging mode | ||
| PV maximum input power | 7.2KW | |
| PV separately charging current | 90A | |
| Nominal Py yoltage | 240Vdc | |
| MPPT voltage range of the PV array | 45~450Vdc/65V opening voltage | |
| Highest PV array open-circuit voltage | 500Vdc | |
| Mixed Maximum Charge Current =Grid Charging + Solar Charging | 100A | |
| Table 4: General Specifications | ||
|---|---|---|
| Security certifications | CE | |
| Operating temperature range | -10°C to 50°C | |
| Storage temperature | -15°C~ 60°C | |
| Store humidity | 5% to 95% Relative humidity (non-condensing) | |
| Dimensions (L*W*H) MM | 360mm*260mm*95mm | |
| Product net weight (KG) | 5.0kg | 5.3kg |
Product Structure Diagram

Notice:
This product is an off-grid inverter,not a grid-connected or parallel inverter. Please be aware of this !